Chinese Journal of Nephrology, Dialysis & Transplantation ›› 2018, Vol. 27 ›› Issue (3): 220-224.DOI: 10.3969/j.issn.1006-298X.2018.03.004
• Article • Previous Articles Next Articles
Online:
Published:
Abstract:
Objective:To discuss the value of the application of photoplethysmography(PPG) for the diagnosis of hemodialysis accessinduced distal ischemia(HAIDI). Methodology:Sixty nine patients with ESRD who were referred to our nephrology department for arteriovenous fistula creation with endtoside anastomosis between June 2016 and december 2016 were included in the prospective cohort study.Patients were asked to take PPG test in peroperative(0~48 h),one day(12~24 h),one month and 3 months after operative,whose measurement indicators included basal digital pressure(BDP),change in digital pressure with access compression(CDP),digital to contralateral brachial index(DBI).And to respond to hand ischemia questionnaire(HIQ) in 1 and 3 month after operation.In addition,groups were divided into HAIDI or no HAIDI according to whether patients with HAIDI symptoms. Results:Sixty two patients underwent followup study,including 15 cases (217%) developed HAIDI,However,the ischemic syndrome in 5 patients had relieved 3 month after operation.BDP and DBI in HAIDI group were significantly lower than the control group in each time after operation (P<0001),CDP in HAIDI group were significantly higher than the control group in 1 and 3 month after operation.BDP and DBI in each time after operation were significantly lower than preoperation in both groups(P<001),In HAIDI group,DBI decreased from 09 to 051,and recovered slightly to 059 in 3 month after operative.However,DBI decreased from 094 to 072 in the control group,and recovered slightly to 083 in 3 month after operative.A drop of DBI in HAIDI group was significantly greater than the control group.HIQ scores in HAIDI group was significantly higher than the control group in 1 and 3 month after operative(10733±5496 vs 574±1175,and 10400±3924 vs 532±1018,P<0001). Conclusion: PPG can be used to detect HAIDI,the diagnostic accuracy of BDP and DBI was higher than CDP,The diagnostic thresholds of HAIDI were 94 mmHg for BDP (sensitivity,667%;specificity,936%),06 for DBI (sensitivity,80%; specificity,83%),65mmHg for CDP(sensitivity,533%;specificity,915%).
Key words: hemodialysis accessinduced distal ischemia, arteriovenous fistula, photoplethysmography
LAI Yanhong,HU Puping,YANG Tao,et al. Application of photoplethysmography in diagnosis of hemodialysis accessinduced distal ischemia[J]. Chinese Journal of Nephrology, Dialysis & Transplantation, 2018, 27(3): 220-224.
0 / / Recommend
Add to citation manager EndNote|Ris|BibTeX
URL: http://www.njcndt.com/EN/10.3969/j.issn.1006-298X.2018.03.004
http://www.njcndt.com/EN/Y2018/V27/I3/220